You are here: Home / Products / Dataloggers
Opus 20E Datalogger for External Sensors: 8120-30K (Kit) includes: OPUS20E Datalogger (8120-30 Temperature and Relative Humidity), Wall Power Supply (8120-NT), 10 Meter Cable (8120-KAB10), Temp/RH Sensor (8120-TFF), Case (BMC1203).
Model: 8120-30K
With up to 10 external channels/sensors per OPUS20E. The OPUS20E offers the highest flexibility and is excellent value for money. It allows the connection of up to 4 external temperature and relative humidity sensors, as well as 2 further analog sensors. Intelligent BUS sensors can be integrated via the OPUS20E’s RS485 interface (e.g. particle counter).
Air flow and differential pressure sensors are typically connected to the OPUS20E via analog inputs as opposed to the maximum of 4 external temperature or humidity sensors that can be integrated via a digital BUS protocol.
In connection with its LAN capabilities, the OPUS20E is able to realize universal measurement networks in real time. For standard applications the Smart-Graph 3 comes into play, and in order to fulfill the 21 CFR 11 guidelines the well established and proven MCPS7 software is available.
To read more information on this product, please Click Here.
OPUS 20E for External Sensors | 8120-30 Datalogger only, or 8120-30K (Kit) |
OPUS 20E for External Sensors POE | 8120-31 |
Dimensions | 6½" x 3" x 1¼" (180mm x 78mm x 32mm) |
Measuring interval | 10/30s, 1/10/12/15/30min, 1/3/6/12/24h |
Storage rate | 1/10/12/15/30min, 1/3/6/12/24h |
Construction | Plastic housing |
Operating life (battery) | <1 year |
Data storage | 16 MB, 3,200,000 measured values |
LC-Display | 3½" x 2½" (90 x 64mm) |
Weight | 8 oz. (250g) |
Included in delivery | PC-Windows Software SmartGraph 3 for graphical and numerical representation of measured values / Instructions/ data cable/ battery/ WAGO connector / DIN rail bracket |
Interface | USB, LAN |
bus interface | RS485 |
Power supply | 4 x LR6 AA Mignon, USB, (POE opt.) |
Operating temperature | -4 to 144°F (-20...50°C) |
Input voltage 0-1V | |
Measurement range | 0....1V |
Accuracy | ±200uV ±0.1% of measured value |
Resolution | <500uV |
Current measurement | |
Measurement range | 2-wires: 4 ... 20mA, 3-wires: 0...20mA |
Accuracy | ±4uA ±0.1% of measured value |
Resolution | <5uA |
Resistance | approx. 50 Ohm |
Thermocouple K | |
Measurement range | -200°C...1200°C |
Accuracy | °°± 1°C ± 0.5% of measured value at -200°C ... 0°C ± 1°C ± 0.2% of measured value at 0°C... 1200°C |
Resolution | < 0.2°C |